High Voltage Gas Discharge Tubes GDT

GTCA28 - High Voltage

  • Electrical Characteristics
    • Catalog # GTCA28-102M-R03
    • DC Sparkover Voltage Tolerance (%) ±20%
    • VNom Spark
      (V)
      1000
    • Max
      Impulse
      Breakdown
      @ 100V/μs
      (V)
      <=1700
    • Capacitance (Co) (pF) <=1
    • Impulse Discharge Current @8/20μs (kA) 3
    • AC
      Discharge
      Current
      (A)
      1
    • Electrodes 2
    • Failsafe Without
    • Operating Temp (Deg C) -40 – 90
    • Product Specification
    • Check Stock
    • Catalog # GTCA28-102M-R03-2
    • DC Sparkover Voltage Tolerance (%) ±20%
    • VNom Spark
      (V)
      1000
    • Max
      Impulse
      Breakdown
      @ 100V/μs
      (V)
      <=1700
    • Capacitance (Co) (pF) <1
    • Impulse Discharge Current @8/20μs (kA) 3
    • AC
      Discharge
      Current
      (A)
      1
    • Electrodes 2
    • Failsafe Without
    • Operating Temp (Deg C) -40 – 90
    • Product Specification
    • Check Stock
    • Catalog # GTCA28-212M-R03
    • DC Sparkover Voltage Tolerance (%) ±20%
    • VNom Spark
      (V)
      2100
    • Max
      Impulse
      Breakdown
      @ 100V/μs
      (V)
      <=2700
    • Capacitance (Co) (pF) <1
    • Impulse Discharge Current @8/20μs (kA) 3
    • AC
      Discharge
      Current
      (A)
      1
    • Electrodes 2
    • Failsafe Without
    • Operating Temp (Deg C) -40 – 90
    • Product Specification
    • Check Stock
    • Catalog # GTCA28-231L-R05
    • DC Sparkover Voltage Tolerance (%) ±15%
    • VNom Spark
      (V)
      230
    • Max
      Impulse
      Breakdown
      @ 100V/μs
      (V)
      <=600
    • Max
      Impulse
      Breakdown
      @ 1kV/μs
      (V)
      <=700
    • Capacitance (Co) (pF) <1
    • Impulse Discharge Current @8/20μs (kA) 5
    • AC
      Discharge
      Current
      (A)
      5
    • Electrodes 2
    • Failsafe Without
    • Operating Temp (Deg C) -40 – 90
    • Product Specification
    • Check Stock Order Sample
    • Catalog # GTCA28-231M-R05
    • DC Sparkover Voltage Tolerance (%) ±20%
    • VNom Spark
      (V)
      230
    • Max
      Impulse
      Breakdown
      @ 100V/μs
      (V)
      <=600
    • Max
      Impulse
      Breakdown
      @ 1kV/μs
      (V)
      <=700
    • Capacitance (Co) (pF) <1
    • Impulse Discharge Current @8/20μs (kA) 5
    • AC
      Discharge
      Current
      (A)
      5
    • Electrodes 2
    • Failsafe Without
    • Operating Temp (Deg C) -40 – 90
    • Product Specification
    • Check Stock Order Sample
    • Catalog # GTCA28-231M-R10
    • DC Sparkover Voltage Tolerance (%) ±20%
    • VNom Spark
      (V)
      230
    • Max
      Impulse
      Breakdown
      @ 100V/μs
      (V)
      <=600
    • Max
      Impulse
      Breakdown
      @ 1kV/μs
      (V)
      <=700
    • Capacitance (Co) (pF) <1
    • Impulse Discharge Current @8/20μs (kA) 10
    • AC
      Discharge
      Current
      (A)
      10
    • Electrodes 2
    • Failsafe Without
    • Operating Temp (Deg C) -40 – 90
    • Product Specification
    • Check Stock Order Sample
    • Catalog # GTCA28-272L-R03
    • DC Sparkover Voltage Tolerance (%) ±15%
    • VNom Spark
      (V)
      2700
    • Max
      Impulse
      Breakdown
      @ 100V/μs
      (V)
      <=3700
    • Capacitance (Co) (pF) <1
    • Impulse Discharge Current @8/20μs (kA) 3
    • Electrodes 2
    • Failsafe Without
    • Operating Temp (Deg C) -40 – 90
    • Product Specification
    • Check Stock
    • Catalog # GTCA28-302M-R03
    • DC Sparkover Voltage Tolerance (%) ±20%
    • VNom Spark
      (V)
      3000
    • Max
      Impulse
      Breakdown
      @ 100V/μs
      (V)
      <=4000
    • Capacitance (Co) (pF) <=1
    • Impulse Discharge Current @8/20μs (kA) 3
    • AC
      Discharge
      Current
      (A)
      1
    • Electrodes 2
    • Failsafe Without
    • Operating Temp (Deg C) -40 – 90
    • Product Specification
    • Check Stock
    • Catalog # GTCA28-302M-R03-2
    • DC Sparkover Voltage Tolerance (%) ±20%
    • VNom Spark
      (V)
      3000
    • Max
      Impulse
      Breakdown
      @ 100V/μs
      (V)
      <=4000
    • Capacitance (Co) (pF) <=1
    • Impulse Discharge Current @8/20μs (kA) 3
    • Electrodes 2
    • Failsafe Without
    • Operating Temp (Deg C) -40 – 90
    • Product Specification
    • Check Stock
    • Catalog # GTCA28-351M-R10
    • DC Sparkover Voltage Tolerance (%) ±20%
    • VNom Spark
      (V)
      350
    • Max
      Impulse
      Breakdown
      @ 100V/μs
      (V)
      <=900
    • Max
      Impulse
      Breakdown
      @ 1kV/μs
      (V)
      <=1000
    • Capacitance (Co) (pF) <1
    • Impulse Discharge Current @8/20μs (kA) 10
    • AC
      Discharge
      Current
      (A)
      10
    • Electrodes 2
    • Failsafe Without
    • Operating Temp (Deg C) -40 – 90
    • Product Specification
    • Check Stock