Neutral Grounding Resistors

SE-330HV

  • Electrical Characteristics
    • Catalog # SE-330HV-00-00
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-00-01
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-01-00
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; DeviceNet
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-01-01
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; DeviceNet
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-03-00
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; Ethernet (Dual RJ45)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-03-01
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; Ethernet (Dual RJ45)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-04-00
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; Ethernet (RJ45 and SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-04-01
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; Ethernet (RJ45 and SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-05-00
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; Ethernet (Dual SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-05-01
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; Ethernet (Dual SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-06-00
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; IEC61850 (Dual RJ45)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-06-01
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; IEC61850 (Dual RJ45)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-07-00
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; IEC61850 (RJ45 and SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-07-01
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; IEC61850 (RJ45 and SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-08-00
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; IEC61850 (Dual SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-08-01
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; IEC61850 (Dual SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-20-00
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-20-01
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-21-00
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; DeviceNet
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-21-01
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; DeviceNet
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-23-00
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; Ethernet (Dual RJ45)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-23-01
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; Ethernet (Dual RJ45)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-24-00
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; Ethernet (RJ45 and SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-24-01
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; Ethernet (RJ45 and SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-25-00
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; Ethernet (Dual SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-25-01
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; Ethernet (Dual SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-26-00
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; IEC61850 (Dual RJ45)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-26-01
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; IEC61850 (Dual RJ45)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-27-00
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; IEC61850 (RJ45 and SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-27-01
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; IEC61850 (RJ45 and SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-28-00
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; IEC61850 (Dual SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330HV-28-01
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; IEC61850 (Dual SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      100 - 10000 (systems up to 35 kV); 200 - 20000 (72 kV systems)
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample