Intrinsically Safe Relay

ISS 105

  • Electrical Characteristics
    • Catalog # ISS-105
    • Input
      Voltage (V)
      120 Vac
    • Termination Type Torque: 3.5 to 4.5 in-lbs (max. 6 in.-lbs); Wire: 12 - 20 AWG
    • Mounting Method 35mm DIN rail or Surface Mount (#6 or #8 screws)
    • Dimensions 2.35 H x 3.7 W x 5.03 D in. (59.7 x 94.1 x 127.6 mm)
    • Weight (lbs/g) 0 Kg
    • Humidity 10 - 95% non-condensing per IEC 68-2-3
    • Input AC Line Frequency (Hz) 50 / 60 (50 will increase all delay timers by 20%)
    • Input Tolerance (%) ±10%
    • Intrinsically Safe Circuit Location Division 1 and 2; Class I Groups A B C D; Class II Groups E F G; Class III
    • Maximum Input Power 5
    • Output Load Rating (VA) Pilot Duty: 480 VA @ 240 Vac B300; General Purpose: 7 A @ 240 Vac
    • Protection Class IP20 (finger safe)
    • Sense Voltage 5 Vdc continuous (probe)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # ISS-105-ISO
    • Input
      Voltage (V)
      120 Vac
    • Termination Type Torque: 3.5 to 4.5 in-lbs (max. 6 in.-lbs); Wire: 12 - 20 AWG
    • Mounting Method 35mm DIN rail or Surface Mount (#6 or #8 screws)
    • Dimensions 2.35 H x 3.7 W x 5.03 D in. (59.7 x 94.1 x 127.6 mm)
    • Weight (lbs/g) 0 Kg
    • Debounce Time Delay (s) 2
    • Humidity 10 - 95% non-condensing per IEC 68-2-3
    • Input AC Line Frequency (Hz) 50 / 60 (50 will increase all delay timers by 20%)
    • Input Logic Input/Output Channels: 5 channels
    • Input Tolerance (%) ±10%
    • Intrinsically Safe Circuit Location Division 1 and 2; Class I Groups A B C D; Class II Groups E F G; Class III
    • Maximum Input Power 5
    • Output Load Rating (VA) Pilot Duty: 480 VA @ 240 Vac B300; General Purpose: 7 A @ 240 Vac
    • Protection Class IP20 (finger safe)
    • Sense Voltage 5 Vdc continuous (probe)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # ISS-105-ISO-3
    • Input
      Voltage (V)
      120 Vac
    • Termination Type Torque: 3.5 to 4.5 in-lbs (max. 6 in.-lbs); Wire: 12 - 20 AWG
    • Mounting Method 35mm DIN rail or Surface Mount (#6 or #8 screws)
    • Dimensions 2.35 H x 3.7 W x 5.03 D in. (59.7 x 94.1 x 127.6 mm)
    • Weight (lbs/g) 0 Kg
    • Debounce Time Delay (s) 2
    • Humidity 10 - 95% non-condensing per IEC 68-2-3
    • Input AC Line Frequency (Hz) 50 / 60 (50 will increase all delay timers by 20%)
    • Input Logic Input/Output Channels: 3 channels
    • Input Tolerance (%) ±10%
    • Intrinsically Safe Circuit Location Division 1 and 2; Class I Groups A B C D; Class II Groups E F G; Class III
    • Maximum Input Power 5
    • Output Load Rating (VA) Pilot Duty: 480 VA @ 240 Vac B300; General Purpose: 7 A @ 240 Vac
    • Protection Class IP20 (finger safe)
    • Sense Voltage 5 Vdc continuous (probe)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # ISS-105-ISO-4
    • Input
      Voltage (V)
      120 Vac
    • Termination Type Torque: 3.5 to 4.5 in-lbs (max. 6 in.-lbs); Wire: 12 - 20 AWG
    • Mounting Method 35mm DIN rail or Surface Mount (#6 or #8 screws)
    • Dimensions 2.35 H x 3.7 W x 5.03 D in. (59.7 x 94.1 x 127.6 mm)
    • Weight (lbs/g) 0 Kg
    • Debounce Time Delay (s) 2
    • Humidity 10 - 95% non-condensing per IEC 68-2-3
    • Input AC Line Frequency (Hz) 50 / 60 (50 will increase all delay timers by 20%)
    • Input Logic Input/Output Channels: 4 channels
    • Input Tolerance (%) ±10%
    • Intrinsically Safe Circuit Location Division 1 and 2; Class I Groups A B C D; Class II Groups E F G; Class III
    • Maximum Input Power 5
    • Output Load Rating (VA) Pilot Duty: 480 VA @ 240 Vac B300; General Purpose: 7 A @ 240 Vac
    • Protection Class IP20 (finger safe)
    • Sense Voltage 5 Vdc continuous (probe)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # ISS-105-ISO-F
    • Input
      Voltage (V)
      120 Vac
    • Termination Type Torque: 3.5 to 4.5 in-lbs (max. 6 in.-lbs); Wire: 12 - 20 AWG
    • Mounting Method 35mm DIN rail or Surface Mount (#6 or #8 screws)
    • Dimensions 2.35 H x 3.7 W x 5.03 D in. (59.7 x 94.1 x 127.6 mm)
    • Weight (lbs/g) 0 Kg
    • Debounce Time Delay (s) 2
    • Humidity 10 - 95% non-condensing per IEC 68-2-3
    • Input AC Line Frequency (Hz) 50 / 60 (50 will increase all delay timers by 20%)
    • Input Logic Input/Output Channels: 5 channels faster response time (≤75 s)
    • Input Tolerance (%) ±10%
    • Intrinsically Safe Circuit Location Division 1 and 2; Class I Groups A B C D; Class II Groups E F G; Class III
    • Maximum Input Power 5
    • Output Load Rating (VA) Pilot Duty: 480 VA @ 240 Vac B300; General Purpose: 7 A @ 240 Vac
    • Protection Class IP20 (finger safe)
    • Sense Voltage 5 Vdc continuous (probe)
    • Datasheet
    • Check Stock Order Sample