Motor and Pump Protection

777

  • Electrical Characteristics
    • Catalog # 777-575-HRG-P2
    • Input
      Voltage (V)
      500 to 600VAC
    • Output
      Form
      SPDT - Form C
    • Termination Type Torque: 7in-lbs
    • Mounting Method Surface mount (4 - #8 screws) on DIN rail mount
    • Full Load Amp Range (A) 2 - 20A (looped conductors only); 20 - 90A direct
    • Dimensions 3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm)
    • Weight (lbs/g) 1.56 lbs. (25.0 oz. 707.6 g)
    • Catalog # 777-575-LR-P2
    • Input
      Voltage (V)
      500 to 600VAC
    • Output
      Form
      SPDT - Form C
    • Termination Type Torque: 7in-lbs
    • Mounting Method Surface mount (4 - #8 screws) on DIN rail mount
    • Full Load Amp Range (A) 1 - 9A 10 - 800A (external CTs required)
    • Dimensions 3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm)
    • Weight (lbs/g) 1.56 lbs. (25.0 oz. 707.6 g)
    • Catalog # 777-575-P2
    • Input
      Voltage (V)
      500 to 600VAC
    • Output
      Form
      SPDT - Form C
    • Termination Type Torque: 7in-lbs
    • Mounting Method Surface mount (4 - #8 screws) on DIN rail mount
    • Full Load Amp Range (A) 2 - 20A (looped conductors required); 20 - 80A (direct); 90 - 800A (external CTs required)
    • Dimensions 3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm)
    • Weight (lbs/g) 1.56 lbs. (25.0 oz. 707.6 g)
    • Catalog # 777-575-TS
    • Input
      Voltage (V)
      500 to 600VAC
    • Output
      Form
      SPDT - Form C
    • Termination Type Torque: 7in-lbs
    • Mounting Method Surface mount (4 - #8 screws) on DIN rail mount
    • Full Load Amp Range (A) 2 - 25A 3 phase (loops required); 25 - 90A 3 phase (direct); 80 - 800A 3 phase (external CTs)
    • Dimensions 3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm)
    • Weight (lbs/g) 1.56 lbs. (25.0 oz. 707.6 g)
    • Catalog # 777-FT
    • Input
      Voltage (V)
      200 - 480VAC
    • Output
      Form
      SPDT - Form C
    • Termination Type Torque: 7in-lbs
    • Mounting Method Surface mount (4 - #8 screws) on DIN rail mount
    • Full Load Amp Range (A) 2 - 25A 3 phase (loops required); 25 - 90A 3 phase (direct); 80 - 800A 3 phase (external CTs)
    • Dimensions 3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm)
    • Weight (lbs/g) 1.56 lbs. (25.0 oz. 707.6 g)
    • Catalog # 777-HRG-P2
    • Input
      Voltage (V)
      200 to 480VAC
    • Output
      Form
      SPDT - Form C
    • Termination Type Torque: 7in-lbs
    • Mounting Method Surface mount (4 - #8 screws) on DIN rail mount
    • Full Load Amp Range (A) 2 - 20A (looped conductors required); 20 - 90A (direct)
    • Dimensions 3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm)
    • Weight (lbs/g) 1.56 lbs. (25.0 oz. 707.6 g)
    • Catalog # 777-HVR-LR-P2
    • Input
      Voltage (V)
      340 to 480VAC
    • Output
      Form
      SPDT - Form C
    • Termination Type Torque: 7in-lbs
    • Mounting Method Surface mount (4 - #8 screws) on DIN rail mount
    • Full Load Amp Range (A) 1 - 9A (direct); 10 - 800A (with external CTs)
    • Dimensions 3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm)
    • Weight (lbs/g) 1.56 lbs. (25.0 oz. 707.6 g)
    • Catalog # 777-HVR-P2
    • Input
      Voltage (V)
      340 to 480VAC
    • Output
      Form
      SPDT - Form C
    • Termination Type Torque: 7in-lbs
    • Mounting Method Surface mount (4 - #8 screws) on DIN rail mount
    • Full Load Amp Range (A) 2 - 20A (looped conductors required); 20 - 90A (direct); 90 - 800A (external CTs required)
    • Dimensions 3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm)
    • Weight (lbs/g) 1.56 lbs. (25.0 oz. 707.6 g)
    • Catalog # 777-LR-HRG-P2
    • Input
      Voltage (V)
      200 to 480VAC
    • Output
      Form
      SPDT - Form C
    • Termination Type Torque: 7in-lbs
    • Mounting Method Surface mount (4 - #8 screws) on DIN rail mount
    • Full Load Amp Range (A) 10 - 800A (external CTs required external zero-seq. CT required)
    • Dimensions 3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm)
    • Weight (lbs/g) 1.56 lbs. (25.0 oz. 707.6 g)
    • Catalog # 777-LR-P2
    • Input
      Voltage (V)
      200 to 480VAC
    • Output
      Form
      SPDT - Form C
    • Termination Type Torque: 7in-lbs
    • Mounting Method Surface mount (4 - #8 screws) on DIN rail mount
    • Full Load Amp Range (A) 1 - 9A 10 - 800A (with external CTs)
    • Dimensions 3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm)
    • Weight (lbs/g) 1.56 lbs. (25.0 oz. 707.6 g)
    • Catalog # 777-LR-TS
    • Input
      Voltage (V)
      200 to 480VAC
    • Output
      Form
      SPDT - Form C
    • Termination Type Torque: 7in-lbs
    • Mounting Method Surface mount (4 - #8 screws) on DIN rail mount
    • Full Load Amp Range (A) 1 - 4.5A 3 phase (loops required); 2 - 9A 3 phase (direct)
    • Dimensions 3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm)
    • Weight (lbs/g) 1.56 lbs. (25.0 oz. 707.6 g)
    • Catalog # 777-MRSW
    • Mounting Method Connect 9-pin adapter to 777 communication port
    • Dimensions 24î (609.6 mm) long
    • Catalog # 777-MV-P2
    • Input
      Voltage (V)
      100 to 240VAC
    • Output
      Form
      SPDT - Form C
    • Termination Type Torque: 7in-lbs
    • Mounting Method Surface mount (4 - #8 screws) on DIN rail mount
    • Full Load Amp Range (A) 10 - 800A (external CTs required)
    • Dimensions 3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm)
    • Weight (lbs/g) 1.56 lbs. (25.0 oz. 707.6 g)
    • Catalog # 777-P2
    • Input
      Voltage (V)
      200 to 480VAC
    • Output
      Form
      SPDT - Form C
    • Termination Type Torque: 7in-lbs
    • Mounting Method Surface mount (4 - #8 screws) on DIN rail mount
    • Full Load Amp Range (A) 2 - 20A (looped conductors required); 20 - 90A (direct); 80 - 800A (external CTs required)
    • Dimensions 3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm)
    • Weight (lbs/g) 1.56 lbs. (25.0 oz. 707.6 g)
    • Catalog # 777-TS
    • Input
      Voltage (V)
      200 to 480VAC
    • Output
      Form
      SPDT - Form C
    • Termination Type Torque: 7in-lbs
    • Mounting Method Surface mount (4 - #8 screws) on DIN rail mount
    • Full Load Amp Range (A) 2 - 25A 3 phase (loops required); 25 - 90A 3 phase (direct); 80 - 800A 3 phase (external CTs)
    • Dimensions 3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm)
    • Weight (lbs/g) 1.56 lbs. (25.0 oz. 707.6 g)
    • Catalog # 777VA-02
    • Input
      Voltage (V)
      200 to 480VAC
    • Output
      Form
      SPDT - Form C
    • Termination Type Torque: 7in-lbs
    • Mounting Method Surface mount (4 - #8 screws) on DIN rail mount
    • Full Load Amp Range (A) 2 - 25A (looped conductors required); 25 - 90A (direct); 80 - 800A (external CTs required)
    • Dimensions 3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm)
    • Weight (lbs/g) 1.56 lbs. (25.0 oz. 707.6 g)
    • Catalog # 777VA-03
    • Input
      Voltage (V)
      200 to 480VAC
    • Output
      Form
      SPDT - Form C
    • Termination Type Torque: 7in-lbs
    • Mounting Method Surface mount (4 - #8 screws) on DIN rail mount
    • Full Load Amp Range (A) 2 - 25A (looped conductors required); 25 - 90A (direct); 80 - 800A (external CTs required)
    • Dimensions 3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm)
    • Weight (lbs/g) 1.56 lbs. (25.0 oz. 707.6 g)