Neutral Grounding Resistors

SE-330

  • Electrical Characteristics
    • Catalog # SE-330-00-00
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-00-01
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-01-00
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; DeviceNet
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-01-01
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; DeviceNet
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-03-00
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; Ethernet (Dual RJ45)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-03-01
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; Ethernet (Dual RJ45)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-04-00
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; Ethernet (RJ45 and SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.1
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-04-01
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; Ethernet (RJ45 and SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.1
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-05-00
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; Ethernet (Dual SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.3
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-05-01
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; Ethernet (Dual SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.4
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-06-00
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; IEC61850 (Dual RJ45)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.5
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-06-01
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; IEC61850 (Dual RJ45)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.6
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-07-00
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; IEC61850 (RJ45 and SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.7
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-07-01
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; IEC61850 (RJ45 and SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.8
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-08-00
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; IEC61850 (Dual SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.9
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-08-01
    • Supply
      Voltage
      VAC
      65 - 265
    • Supply
      Voltage
      VDC
      85 - 275
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; IEC61850 (Dual SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.10
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-20-00
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-20-01
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-21-00
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; DeviceNet
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-21-01
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; DeviceNet
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-23-00
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; Ethernet (Dual RJ45)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 87
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 3 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.1
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-23-01
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; Ethernet (Dual RJ45)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.0
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-24-00
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; Ethernet (RJ45 and SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.1
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-24-01
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; Ethernet (RJ45 and SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.1
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-25-00
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; Ethernet (Dual SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.1
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-25-01
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; Ethernet (Dual SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.1
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-26-00
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; IEC61850 (Dual RJ45)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.1
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-26-01
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; IEC61850 (Dual RJ45)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.1
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-27-00
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; IEC61850 (RJ45 and SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.1
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-27-01
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; IEC61850 (RJ45 and SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.1
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-28-00
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 2 Form A; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; IEC61850 (Dual SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.1
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample
    • Catalog # SE-330-28-01
    • Supply
      Voltage
      VAC
      28 - 52
    • Supply
      Voltage
      VDC
      36 - 72
    • Relay Contacts Config 1 Form A; 1 Form B; 2 Form C
    • Analog Output Current mA 4 - 20
    • Communications USB; IEC61850 (Dual SC Fiber)
    • New Rev Avail Now
    • Old Rev Avail No longer available
    • IEEE Device Numbers 50G - 50N - 51G - 51N - 59N - 86
    • Relay
      Contact
      Operating
      Fail-safe / Non Fail-safe
    • Dimensions 8.4 H x 3.9 W x 5.8 D in.
    • Weight (lbs/g) 0 Kg
    • Auto Manual Reset Latching; Autoreset
    • Conformally coated Standard
    • Frequency 50; 60; ASD
    • GF Trip Level Range pct 2 - 100% of CT-Primary Rating
    • GF Trip Time s 0.1 - 10.1
    • Harmonic Filtering Standard (DFT)
    • Reset Type Front-panel switch/Remote N.O. Contact
    • RF Trip
      Level
      V
      20 - 2000 (systems up to 5 kV); 100 - 10000 (systems over 5 kV)
    • RF Trip
      Time Delay
      s
      12
    • System type Resistance Grounded AC
    • Datasheet
    • Order Sample