Baseband Voice DS1 Protection

Pxxx2AxL

  • Electrical Characteristics
    • Catalog # P0602AA
    • Obsolete: 2009 -09-01
    • VDRM T-R
      (V)
      50
    • VS T-R
      (V)
      80
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      90
    • CO 2V
      T-R MIN
      (pF)
      10
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 50
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20 (SERIES RESISTANCE NE
      ITU K.20 ENHANCED (SERIES RESI
      ITU K.21 ENHANCED (SERIES RESI
      TIA-968-A (SERIES RESISTANCE N
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 75
    • Ipp10x700 75
    • Ipp2x10 150
    • Ipp5x320 75
    • Ipp8x20 150
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating A
    • Package Modified TO-220
    • Datasheet
    • Catalog # P0602AAL
    • VDRM T-R
      (V)
      50
    • VS T-R
      (V)
      80
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      90
    • CO 2V
      T-R MIN
      (pF)
      10
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 50
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20 (SERIES RESISTANCE NE
      ITU K.20 ENHANCED (SERIES RESI
      ITU K.21 ENHANCED (SERIES RESI
      TIA-968-A (SERIES RESISTANCE N
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 75
    • Ipp10x700 75
    • Ipp2x10 150
    • Ipp5x320 75
    • Ipp8x20 150
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating A
    • Package Modified TO-220
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P0602AB
    • Obsolete: 2009 -09-01
    • VDRM T-R
      (V)
      50
    • VS T-R
      (V)
      80
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      145
    • CO 2V
      T-R MIN
      (pF)
      10
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 50
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY (SE
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 250
    • Ipp5x320 200
    • Ipp8x20 250
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating B
    • Package Modified TO-220
    • Datasheet
    • Catalog # P0602ABL
    • VDRM T-R
      (V)
      50
    • VS T-R
      (V)
      80
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      145
    • CO 2V
      T-R MIN
      (pF)
      10
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 50
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY (SE
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 200
    • Ipp10x700 200
    • Ipp2x10 250
    • Ipp5x320 200
    • Ipp8x20 250
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating B
    • Package Modified TO-220
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P1402AA
    • Obsolete: 2009 -09-01
    • VDRM T-R
      (V)
      116
    • VS T-R
      (V)
      154
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      35
    • CO 2V
      T-R MIN
      (pF)
      20
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20 (SERIES RESISTANCE NE
      ITU K.20 ENHANCED (SERIES RESI
      ITU K.21 ENHANCED (SERIES RESI
      TIA-968-A (SERIES RESISTANCE N
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 75
    • Ipp10x700 75
    • Ipp2x10 150
    • Ipp5x320 75
    • Ipp8x20 150
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating A
    • Package Modified TO-220
    • Datasheet
    • Catalog # P1402AAL
    • VDRM T-R
      (V)
      116
    • VS T-R
      (V)
      154
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      35
    • CO 2V
      T-R MIN
      (pF)
      20
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20 (SERIES RESISTANCE NE
      ITU K.20 ENHANCED (SERIES RESI
      ITU K.21 ENHANCED (SERIES RESI
      TIA-968-A (SERIES RESISTANCE N
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 75
    • Ipp10x700 75
    • Ipp2x10 150
    • Ipp5x320 75
    • Ipp8x20 150
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating A
    • Package Modified TO-220
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P1402AB
    • Obsolete: 2009 -09-01
    • VDRM T-R
      (V)
      116
    • VS T-R
      (V)
      154
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      90
    • CO 2V
      T-R MIN
      (pF)
      20
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY (SE
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 100
    • Ipp10x700 100
    • Ipp2x10 250
    • Ipp5x320 100
    • Ipp8x20 250
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating B
    • Package Modified TO-220
    • Datasheet
    • Catalog # P1402ABL
    • VDRM T-R
      (V)
      116
    • VS T-R
      (V)
      154
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      90
    • CO 2V
      T-R MIN
      (pF)
      20
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY (SE
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 100
    • Ipp10x700 100
    • Ipp2x10 250
    • Ipp5x320 100
    • Ipp8x20 250
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating B
    • Package Modified TO-220
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P1602AA
    • Obsolete: 2009 -09-01
    • VDRM T-R
      (V)
      130
    • VS T-R
      (V)
      190
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      35
    • CO 2V
      T-R MIN
      (pF)
      20
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20 (SERIES RESISTANCE NE
      ITU K.20 ENHANCED (SERIES RESI
      ITU K.21 ENHANCED (SERIES RESI
      TIA-968-A (SERIES RESISTANCE N
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 75
    • Ipp10x700 75
    • Ipp2x10 150
    • Ipp5x320 75
    • Ipp8x20 150
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating A
    • Package Modified TO-220
    • Datasheet
    • Catalog # P1602AAL
    • VDRM T-R
      (V)
      130
    • VS T-R
      (V)
      190
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      35
    • CO 2V
      T-R MIN
      (pF)
      20
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20 (SERIES RESISTANCE NE
      ITU K.20 ENHANCED (SERIES RESI
      ITU K.21 ENHANCED (SERIES RESI
      TIA-968-A (SERIES RESISTANCE N
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 75
    • Ipp10x700 75
    • Ipp2x10 150
    • Ipp5x320 75
    • Ipp8x20 150
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating A
    • Package Modified TO-220
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P1602AB
    • Obsolete: 2009 -09-01
    • VDRM T-R
      (V)
      130
    • VS T-R
      (V)
      190
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      85
    • CO 2V
      T-R MIN
      (pF)
      20
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY (SE
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 100
    • Ipp10x700 100
    • Ipp2x10 250
    • Ipp5x320 100
    • Ipp8x20 250
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating B
    • Package Modified TO-220
    • Datasheet
    • Catalog # P1602ABL
    • VDRM T-R
      (V)
      130
    • VS T-R
      (V)
      190
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      85
    • CO 2V
      T-R MIN
      (pF)
      20
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY (SE
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 100
    • Ipp10x700 100
    • Ipp2x10 250
    • Ipp5x320 100
    • Ipp8x20 250
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating B
    • Package Modified TO-220
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P2202AA
    • Obsolete: 2009 -09-01
    • VDRM T-R
      (V)
      180
    • VS T-R
      (V)
      260
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      30
    • CO 2V
      T-R MIN
      (pF)
      15
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20 (SERIES RESISTANCE NE
      ITU K.20 ENHANCED (SERIES RESI
      ITU K.21 ENHANCED (SERIES RESI
      TIA-968-A (SERIES RESISTANCE N
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 75
    • Ipp10x700 75
    • Ipp2x10 150
    • Ipp5x320 75
    • Ipp8x20 150
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating A
    • Package Modified TO-220
    • Datasheet
    • Catalog # P2202AAL
    • VDRM T-R
      (V)
      180
    • VS T-R
      (V)
      260
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      30
    • CO 2V
      T-R MIN
      (pF)
      15
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20 (SERIES RESISTANCE NE
      ITU K.20 ENHANCED (SERIES RESI
      ITU K.21 ENHANCED (SERIES RESI
      TIA-968-A (SERIES RESISTANCE N
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 75
    • Ipp10x700 75
    • Ipp2x10 150
    • Ipp5x320 75
    • Ipp8x20 150
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating A
    • Package Modified TO-220
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P2202AB
    • Obsolete: 2009 -09-01
    • VDRM T-R
      (V)
      180
    • VS T-R
      (V)
      260
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      65
    • CO 2V
      T-R MIN
      (pF)
      15
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY (SE
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 100
    • Ipp10x700 100
    • Ipp2x10 250
    • Ipp5x320 100
    • Ipp8x20 250
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating B
    • Package Modified TO-220
    • Datasheet
    • Catalog # P2202ABL
    • VDRM T-R
      (V)
      180
    • VS T-R
      (V)
      260
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      65
    • CO 2V
      T-R MIN
      (pF)
      15
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY (SE
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 100
    • Ipp10x700 100
    • Ipp2x10 250
    • Ipp5x320 100
    • Ipp8x20 250
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating B
    • Package Modified TO-220
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P2702AA
    • Obsolete: 2009 -09-01
    • VDRM T-R
      (V)
      240
    • VS T-R
      (V)
      320
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      25
    • CO 2V
      T-R MIN
      (pF)
      15
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20 (SERIES RESISTANCE NE
      ITU K.20 ENHANCED (SERIES RESI
      ITU K.21 ENHANCED (SERIES RESI
      TIA-968-A (SERIES RESISTANCE N
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 75
    • Ipp10x700 75
    • Ipp2x10 150
    • Ipp5x320 75
    • Ipp8x20 150
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating A
    • Package Modified TO-220
    • Datasheet
    • Catalog # P2702AAL
    • VDRM T-R
      (V)
      240
    • VS T-R
      (V)
      320
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      25
    • CO 2V
      T-R MIN
      (pF)
      15
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20 (SERIES RESISTANCE NE
      ITU K.20 ENHANCED (SERIES RESI
      ITU K.21 ENHANCED (SERIES RESI
      TIA-968-A (SERIES RESISTANCE N
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 75
    • Ipp10x700 75
    • Ipp2x10 150
    • Ipp5x320 75
    • Ipp8x20 150
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating A
    • Package Modified TO-220
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P2702AB
    • Obsolete: 2009 -09-01
    • VDRM T-R
      (V)
      240
    • VS T-R
      (V)
      320
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      60
    • CO 2V
      T-R MIN
      (pF)
      15
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY (SE
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 100
    • Ipp10x700 100
    • Ipp2x10 250
    • Ipp5x320 100
    • Ipp8x20 250
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating B
    • Package Modified TO-220
    • Datasheet
    • Catalog # P2702ABL
    • VDRM T-R
      (V)
      240
    • VS T-R
      (V)
      320
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      60
    • CO 2V
      T-R MIN
      (pF)
      15
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY (SE
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 100
    • Ipp10x700 100
    • Ipp2x10 250
    • Ipp5x320 100
    • Ipp8x20 250
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating B
    • Package Modified TO-220
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P3002AA
    • Obsolete: 2009 -09-01
    • VDRM T-R
      (V)
      280
    • VS T-R
      (V)
      360
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      25
    • CO 2V
      T-R MIN
      (pF)
      15
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20 (SERIES RESISTANCE NE
      ITU K.20 ENHANCED (SERIES RESI
      ITU K.21 ENHANCED (SERIES RESI
      TIA-968-A (SERIES RESISTANCE N
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 75
    • Ipp10x700 75
    • Ipp2x10 150
    • Ipp5x320 75
    • Ipp8x20 150
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating A
    • Package Modified TO-220
    • Datasheet
    • Catalog # P3002AAL
    • VDRM T-R
      (V)
      280
    • VS T-R
      (V)
      360
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      25
    • CO 2V
      T-R MIN
      (pF)
      15
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20 (SERIES RESISTANCE NE
      ITU K.20 ENHANCED (SERIES RESI
      ITU K.21 ENHANCED (SERIES RESI
      TIA-968-A (SERIES RESISTANCE N
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 75
    • Ipp10x700 75
    • Ipp2x10 150
    • Ipp5x320 75
    • Ipp8x20 150
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating A
    • Package Modified TO-220
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P3002AB
    • Obsolete: 2009 -09-01
    • VDRM T-R
      (V)
      280
    • VS T-R
      (V)
      360
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      55
    • CO 2V
      T-R MIN
      (pF)
      15
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY (SE
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 100
    • Ipp10x700 100
    • Ipp2x10 250
    • Ipp5x320 100
    • Ipp8x20 250
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating B
    • Package Modified TO-220
    • Datasheet
    • Catalog # P3002ABL
    • VDRM T-R
      (V)
      280
    • VS T-R
      (V)
      360
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      55
    • CO 2V
      T-R MIN
      (pF)
      15
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY (SE
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 100
    • Ipp10x700 100
    • Ipp2x10 250
    • Ipp5x320 100
    • Ipp8x20 250
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating B
    • Package Modified TO-220
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P3602AA
    • Obsolete: 2009 -09-01
    • VDRM T-R
      (V)
      340
    • VS T-R
      (V)
      440
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      20
    • CO 2V
      T-R MIN
      (pF)
      10
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20 (SERIES RESISTANCE NE
      ITU K.20 ENHANCED (SERIES RESI
      ITU K.21 ENHANCED (SERIES RESI
      TIA-968-A (SERIES RESISTANCE N
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 75
    • Ipp10x700 75
    • Ipp2x10 150
    • Ipp5x320 75
    • Ipp8x20 150
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating A
    • Package Modified TO-220
    • Datasheet
    • Catalog # P3602AAL
    • VDRM T-R
      (V)
      340
    • VS T-R
      (V)
      440
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      20
    • CO 2V
      T-R MIN
      (pF)
      10
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20 (SERIES RESISTANCE NE
      ITU K.20 ENHANCED (SERIES RESI
      ITU K.21 ENHANCED (SERIES RESI
      TIA-968-A (SERIES RESISTANCE N
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 75
    • Ipp10x700 75
    • Ipp2x10 150
    • Ipp5x320 75
    • Ipp8x20 150
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating A
    • Package Modified TO-220
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P3602AB
    • Obsolete: 2009 -09-01
    • VDRM T-R
      (V)
      340
    • VS T-R
      (V)
      440
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      50
    • CO 2V
      T-R MIN
      (pF)
      10
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY (SE
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 100
    • Ipp10x700 100
    • Ipp2x10 250
    • Ipp5x320 100
    • Ipp8x20 250
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating B
    • Package Modified TO-220
    • Datasheet
    • Catalog # P3602ABL
    • VDRM T-R
      (V)
      340
    • VS T-R
      (V)
      440
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      50
    • CO 2V
      T-R MIN
      (pF)
      10
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY (SE
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 100
    • Ipp10x700 100
    • Ipp2x10 250
    • Ipp5x320 100
    • Ipp8x20 250
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating B
    • Package Modified TO-220
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P4202AA
    • Obsolete: 2009 -09-01
    • VDRM T-R
      (V)
      380
    • VS T-R
      (V)
      500
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      20
    • CO 2V
      T-R MIN
      (pF)
      10
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20 (SERIES RESISTANCE NE
      ITU K.20 ENHANCED (SERIES RESI
      ITU K.21 ENHANCED (SERIES RESI
      TIA-968-A (SERIES RESISTANCE N
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 75
    • Ipp10x700 75
    • Ipp2x10 150
    • Ipp5x320 75
    • Ipp8x20 150
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating A
    • Package Modified TO-220
    • Datasheet
    • Catalog # P4202AAL
    • VDRM T-R
      (V)
      380
    • VS T-R
      (V)
      500
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      20
    • CO 2V
      T-R MIN
      (pF)
      10
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20 (SERIES RESISTANCE NE
      ITU K.20 ENHANCED (SERIES RESI
      ITU K.21 ENHANCED (SERIES RESI
      TIA-968-A (SERIES RESISTANCE N
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 75
    • Ipp10x700 75
    • Ipp2x10 150
    • Ipp5x320 75
    • Ipp8x20 150
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating A
    • Package Modified TO-220
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P4202AB
    • Obsolete: 2009 -09-01
    • VDRM T-R
      (V)
      380
    • VS T-R
      (V)
      500
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      50
    • CO 2V
      T-R MIN
      (pF)
      10
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY (SE
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 100
    • Ipp10x700 100
    • Ipp2x10 250
    • Ipp5x320 100
    • Ipp8x20 250
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating B
    • Package Modified TO-220
    • Datasheet
    • Catalog # P4202ABL
    • VDRM T-R
      (V)
      380
    • VS T-R
      (V)
      500
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      50
    • CO 2V
      T-R MIN
      (pF)
      10
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY (SE
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 100
    • Ipp10x700 100
    • Ipp2x10 250
    • Ipp5x320 100
    • Ipp8x20 250
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating B
    • Package Modified TO-220
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P4802AA
    • Obsolete: 2009 -09-01
    • VDRM T-R
      (V)
      440
    • VS T-R
      (V)
      600
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      20
    • CO 2V
      T-R MIN
      (pF)
      10
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20 (SERIES RESISTANCE NE
      ITU K.20 ENHANCED (SERIES RESI
      ITU K.21 ENHANCED (SERIES RESI
      TIA-968-A (SERIES RESISTANCE N
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 75
    • Ipp10x700 75
    • Ipp2x10 150
    • Ipp5x320 75
    • Ipp8x20 150
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating A
    • Package Modified TO-220
    • Datasheet
    • Catalog # P4802AAL
    • VDRM T-R
      (V)
      440
    • VS T-R
      (V)
      600
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      20
    • CO 2V
      T-R MIN
      (pF)
      10
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20 (SERIES RESISTANCE NE
      ITU K.20 ENHANCED (SERIES RESI
      ITU K.21 ENHANCED (SERIES RESI
      TIA-968-A (SERIES RESISTANCE N
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 75
    • Ipp10x700 75
    • Ipp2x10 150
    • Ipp5x320 75
    • Ipp8x20 150
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating A
    • Package Modified TO-220
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P4802AB
    • Obsolete: 2009 -09-01
    • VDRM T-R
      (V)
      440
    • VS T-R
      (V)
      600
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      50
    • CO 2V
      T-R MIN
      (pF)
      10
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY (SE
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 100
    • Ipp10x700 100
    • Ipp2x10 250
    • Ipp5x320 100
    • Ipp8x20 250
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating B
    • Package Modified TO-220
    • Datasheet
    • Catalog # P4802ABL
    • VDRM T-R
      (V)
      440
    • VS T-R
      (V)
      600
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      50
    • CO 2V
      T-R MIN
      (pF)
      10
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY (SE
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 100
    • Ipp10x700 100
    • Ipp2x10 250
    • Ipp5x320 100
    • Ipp8x20 250
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating B
    • Package Modified TO-220
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P6002AA
    • Obsolete: 2009 -09-01
    • VDRM T-R
      (V)
      550
    • VS T-R
      (V)
      700
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      20
    • CO 2V
      T-R MIN
      (pF)
      10
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20 (SERIES RESISTANCE NE
      ITU K.20 ENHANCED (SERIES RESI
      ITU K.21 ENHANCED (SERIES RESI
      TIA-968-A (SERIES RESISTANCE N
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 75
    • Ipp10x700 75
    • Ipp2x10 150
    • Ipp5x320 75
    • Ipp8x20 150
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating A
    • Package Modified TO-220
    • Datasheet
    • Catalog # P6002AAL
    • VDRM T-R
      (V)
      550
    • VS T-R
      (V)
      700
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      20
    • CO 2V
      T-R MIN
      (pF)
      10
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20 (SERIES RESISTANCE NE
      ITU K.20 ENHANCED (SERIES RESI
      ITU K.21 ENHANCED (SERIES RESI
      TIA-968-A (SERIES RESISTANCE N
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 75
    • Ipp10x700 75
    • Ipp2x10 150
    • Ipp5x320 75
    • Ipp8x20 150
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating A
    • Package Modified TO-220
    • Datasheet
    • Check Stock Order Sample
    • Catalog # P6002AB
    • Obsolete: 2009 -09-01
    • VDRM T-R
      (V)
      550
    • VS T-R
      (V)
      700
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      45
    • CO 2V
      T-R MIN
      (pF)
      10
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY (SE
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 100
    • Ipp10x700 100
    • Ipp2x10 250
    • Ipp5x320 100
    • Ipp8x20 250
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating B
    • Package Modified TO-220
    • Datasheet
    • Catalog # P6002ABL
    • VDRM T-R
      (V)
      550
    • VS T-R
      (V)
      700
    • Pins T-R 1-3
    • CO 2V
      T-R MAX
      (pF)
      45
    • CO 2V
      T-R MIN
      (pF)
      10
    • Iscurr 800
    • IDRM @
      VDRM
      (μA)
      5
    • IH (mA) 150
    • di/dt @
      110°C
      (A/μs)
      500
    • Regulatory Requirements GR1089 INTER-BUILDING (SERIES
      GR1089 INTRA-BUILDING
      ITU K.20
      ITU K.20 ENHANCED
      ITU K.21 ENHANCED
      TIA-968-A
      YD/T 993-1998 WITH PRIMARY (SE
      YD/T 993-1998 WITHOUT PRIMARY
    • Ipp5x310 100
    • Ipp10x700 100
    • Ipp2x10 250
    • Ipp5x320 100
    • Ipp8x20 250
    • Pins T-G 1-2
    • Pins R-G 3-2
    • Surge Rating B
    • Package Modified TO-220
    • Datasheet
    • Check Stock Order Sample