Mechanical Relays

HCR-6

  • Electrical Characteristics
    • Catalog # 90340
    • Contactor Form per Circuit DPDT
    • Full Load Current Inductive(A) 12
    • Full Load Current Resistive(A) 15
    • Input Voltage Maximum (V) 26.4
    • Mechanical Life Expectancy 1 Million cycles
    • Coil Voltage 24
    • Electrical Life Expectancy Inductive 100,000 operations
    • Electrical Life Expectancy Resistive 250,000 operations
    • Locked Rotor Current 60
    • Mounting Method Chassis Mount
    • Must Release Voltage 4.8
    • Pull In Voltage 20.4
    • Switching Voltage Maximum (V) 24
    • Termination Type 0.250" quick-connect lug terminals
    • Operating Temperature -55° to 125°C
    • Datasheet
    • Catalog # 90341
    • Contactor Form per Circuit DPDT
    • Full Load Current Inductive(A) 12
    • Full Load Current Resistive(A) 15
    • Input Voltage Maximum (V) 132
    • Mechanical Life Expectancy 1 Million cycles
    • Coil Voltage 120
    • Electrical Life Expectancy Inductive 100,000 operations
    • Electrical Life Expectancy Resistive 250,000 operations
    • Locked Rotor Current 60
    • Mounting Method Chassis Mount
    • Must Release Voltage 24
    • Pull In Voltage 102
    • Switching Voltage Maximum (V) 120
    • Termination Type 0.250" quick-connect lug terminals
    • Operating Temperature -55° to 125°C
    • Datasheet
    • Catalog # 90342
    • Contactor Form per Circuit DPDT
    • Full Load Current Inductive(A) 6
    • Full Load Current Resistive(A) 15
    • Input Voltage Maximum (V) 1600
    • Mechanical Life Expectancy 1 Million cycles
    • Coil Voltage 240
    • Electrical Life Expectancy Inductive 100,000 operations
    • Electrical Life Expectancy Resistive 250,000 operations
    • Locked Rotor Current 35
    • Mounting Method Chassis Mount
    • Must Release Voltage 48
    • Pull In Voltage 176
    • Switching Voltage Maximum (V) 208/240
    • Termination Type 0.250" quick-connect lug terminals
    • Operating Temperature -55° to 125°C
    • Datasheet