Nano 2 Fuses

462

  • Electrical Characteristics
    • Catalog # 46205000000
    • Amps (A) 0.5
    • VDC (V) 250
    • VAC (V) 250
    • Nominal Melting I2T (A2sec) 0.43
    • Resistance
      (Ω)
      0.227
    • Interrupting Rating 100A@350VAC 100A@350VDC
    • Body Plastic
    • Min Operating Temp (°C) -40
    • Max Operating Temp (°C) 85
    • Marking Code T500mA 462 L 250V
    • MSL 1
    • Nom
      Voltage
      Drop
      (mV)
      160
    • Opening Slo-Blo/Time Lag (T)/Time Delay
    • Size 10.5 x 4.45mm
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 46206300000
    • Amps (A) 0.63
    • VDC (V) 250
    • VAC (V) 250
    • Nominal Melting I2T (A2sec) 0.8
    • Resistance
      (Ω)
      0.157
    • Interrupting Rating 100A@350VAC 100A@350VDC
    • Body Plastic
    • Min Operating Temp (°C) -40
    • Max Operating Temp (°C) 85
    • Marking Code T630mA 462 L 250V
    • MSL 1
    • Nom
      Voltage
      Drop
      (mV)
      160
    • Opening Slo-Blo/Time Lag (T)/Time Delay
    • Size 10.5 x 4.45mm
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 46208000000
    • Amps (A) 0.8
    • VDC (V) 250
    • VAC (V) 250
    • Nominal Melting I2T (A2sec) 1.4
    • Resistance
      (Ω)
      0.13
    • Interrupting Rating 100A@350VAC 100A@350VDC
    • Body Plastic
    • Min Operating Temp (°C) -40
    • Max Operating Temp (°C) 85
    • Marking Code T800mA 462 L 250V
    • MSL 1
    • Nom
      Voltage
      Drop
      (mV)
      160
    • Opening Slo-Blo/Time Lag (T)/Time Delay
    • Size 10.5 x 4.45mm
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 46211000000
    • Amps (A) 1
    • VDC (V) 250
    • VAC (V) 250
    • Nominal Melting I2T (A2sec) 2.7
    • Resistance
      (Ω)
      0.0867
    • Interrupting Rating 100A@350VAC 100A@350VDC
    • Body Plastic
    • Min Operating Temp (°C) -40
    • Max Operating Temp (°C) 85
    • Marking Code T1A 462 L 250V
    • MSL 1
    • Nom
      Voltage
      Drop
      (mV)
      140
    • Opening Slo-Blo/Time Lag (T)/Time Delay
    • Size 10.5 x 4.45mm
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 46211250000
    • Amps (A) 1.25
    • VDC (V) 250
    • VAC (V) 250
    • Nominal Melting I2T (A2sec) 5.2
    • Resistance
      (Ω)
      0.0602
    • Interrupting Rating 100A@350VAC 100A@350VDC
    • Body Plastic
    • Min Operating Temp (°C) -40
    • Max Operating Temp (°C) 85
    • Marking Code T1.25A 462 L 250V
    • MSL 1
    • Nom
      Voltage
      Drop
      (mV)
      130
    • Opening Slo-Blo/Time Lag (T)/Time Delay
    • Size 10.5 x 4.45mm
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 46211600000
    • Amps (A) 1.6
    • VDC (V) 250
    • VAC (V) 250
    • Nominal Melting I2T (A2sec) 9.7
    • Resistance
      (Ω)
      0.0443
    • Interrupting Rating 100A@350VAC 100A@350VDC
    • Body Plastic
    • Min Operating Temp (°C) -40
    • Max Operating Temp (°C) 85
    • Marking Code T1.6A 462 L 250V
    • MSL 1
    • Nom
      Voltage
      Drop
      (mV)
      130
    • Opening Slo-Blo/Time Lag (T)/Time Delay
    • Size 10.5 x 4.45mm
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 46212000000
    • Amps (A) 2
    • VDC (V) 250
    • VAC (V) 250
    • Nominal Melting I2T (A2sec) 5.44
    • Resistance
      (Ω)
      0.0335
    • Interrupting Rating 100A@350VAC 100A@350VDC
    • Body Plastic
    • Min Operating Temp (°C) -40
    • Max Operating Temp (°C) 85
    • Marking Code T2A 462 L 250V
    • MSL 1
    • Nom
      Voltage
      Drop
      (mV)
      120
    • Opening Slo-Blo/Time Lag (T)/Time Delay
    • Size 10.5 x 4.45mm
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 46212500000
    • Amps (A) 2.5
    • VDC (V) 250
    • VAC (V) 250
    • Nominal Melting I2T (A2sec) 8
    • Resistance
      (Ω)
      0.0278
    • Interrupting Rating 100A@350VAC 100A@350VDC
    • Body Plastic
    • Min Operating Temp (°C) -40
    • Max Operating Temp (°C) 85
    • Marking Code T2.5A 462 L 250V
    • MSL 1
    • Nom
      Voltage
      Drop
      (mV)
      120
    • Opening Slo-Blo/Time Lag (T)/Time Delay
    • Size 10.5 x 4.45mm
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 46213150000
    • Amps (A) 3.15
    • VDC (V) 250
    • VAC (V) 250
    • Nominal Melting I2T (A2sec) 14
    • Resistance
      (Ω)
      0.0204
    • Interrupting Rating 100A@350VAC 100A@350VDC
    • Body Plastic
    • Min Operating Temp (°C) -40
    • Max Operating Temp (°C) 85
    • Marking Code T3.15A 462 L 250V
    • MSL 1
    • Nom
      Voltage
      Drop
      (mV)
      110
    • Opening Slo-Blo/Time Lag (T)/Time Delay
    • Size 10.5 x 4.45mm
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 46214000000
    • Amps (A) 4
    • VDC (V) 250
    • VAC (V) 250
    • Nominal Melting I2T (A2sec) 21
    • Resistance
      (Ω)
      0.0158
    • Interrupting Rating 100A@350VAC 100A@350VDC
    • Body Plastic
    • Min Operating Temp (°C) -40
    • Max Operating Temp (°C) 85
    • Marking Code T4A 462 L 250V
    • MSL 1
    • Nom
      Voltage
      Drop
      (mV)
      110
    • Opening Slo-Blo/Time Lag (T)/Time Delay
    • Size 10.5 x 4.45mm
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 46215000000
    • Amps (A) 5
    • VDC (V) 250
    • VAC (V) 250
    • Nominal Melting I2T (A2sec) 40
    • Resistance
      (Ω)
      0.0124
    • Body Plastic
    • Min Operating Temp (°C) -40
    • Max Operating Temp (°C) 85
    • Marking Code T5A 462 L 250V
    • MSL 1
    • Nom
      Voltage
      Drop
      (mV)
      110
    • Opening Slo-Blo/Time Lag (T)/Time Delay
    • Size 10.5 x 4.45mm
    • Datasheet
    • Check Stock Order Sample