Surface Mount PPTCs

1206L

  • Electrical Characteristics
    • Catalog # 1206L005/60
    • IHold (A) 0.05
    • ITRIP
      (A)
      0.15
    • Max Volts
      (V)
      60
    • IMAX
      (A)
      10
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      3.6
    • R1max
      (Ω)
      20
    • Max
      Time
      To
      Trip
      (A)
      0.25
    • Max
      Time
      to
      Trip Time
      (Sec)
      1.5
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1206L010/60
    • IHold (A) 0.1
    • ITRIP
      (A)
      0.25
    • Max Volts
      (V)
      60
    • IMAX
      (A)
      10
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      1.5
    • R1max
      (Ω)
      10
    • Max
      Time
      To
      Trip
      (A)
      0.5
    • Max
      Time
      to
      Trip Time
      (Sec)
      1.5
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1206L012
    • IHold (A) 0.125
    • ITRIP
      (A)
      0.29
    • Max Volts
      (V)
      30
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      1.5
    • R1max
      (Ω)
      6
    • Max
      Time
      To
      Trip
      (A)
      1
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.2
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1206L012/48
    • IHold (A) 0.125
    • ITRIP
      (A)
      0.29
    • Max Volts
      (V)
      48
    • IMAX
      (A)
      10
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      1.5
    • R1max
      (Ω)
      6
    • Max
      Time
      To
      Trip
      (A)
      1
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.2
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1206L016
    • IHold (A) 0.16
    • ITRIP
      (A)
      0.37
    • Max Volts
      (V)
      30
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      1.2
    • R1max
      (Ω)
      4.5
    • Max
      Time
      To
      Trip
      (A)
      1
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.3
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1206L020
    • IHold (A) 0.2
    • ITRIP
      (A)
      0.42
    • Max Volts
      (V)
      24
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      0.65
    • R1max
      (Ω)
      2.6
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.1
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1206L020/30
    • IHold (A) 0.2
    • ITRIP
      (A)
      0.42
    • Max Volts
      (V)
      30
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      0.65
    • R1max
      (Ω)
      2.6
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.1
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1206L025
    • IHold (A) 0.25
    • ITRIP
      (A)
      0.5
    • Max Volts
      (V)
      16
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      0.55
    • R1max
      (Ω)
      2.3
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.08
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1206L025/24
    • IHold (A) 0.25
    • ITRIP
      (A)
      0.55
    • Max Volts
      (V)
      24
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      0.55
    • R1max
      (Ω)
      2.3
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.08
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1206L035
    • IHold (A) 0.35
    • ITRIP
      (A)
      0.75
    • Max Volts
      (V)
      6
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      0.3
    • R1max
      (Ω)
      1.2
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.1
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1206L035/16
    • IHold (A) 0.35
    • ITRIP
      (A)
      0.75
    • Max Volts
      (V)
      16
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      0.3
    • R1max
      (Ω)
      1.2
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.1
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1206L035/30
    • IHold (A) 0.35
    • ITRIP
      (A)
      0.75
    • Max Volts
      (V)
      30
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      0.3
    • R1max
      (Ω)
      1.2
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.1
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1206L050
    • IHold (A) 0.5
    • ITRIP
      (A)
      1
    • Max Volts
      (V)
      6
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      0.15
    • R1max
      (Ω)
      0.7
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.1
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1206L050/15
    • IHold (A) 0.5
    • ITRIP
      (A)
      1
    • Max Volts
      (V)
      15
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      0.15
    • R1max
      (Ω)
      0.75
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.1
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1206L050/24
    • IHold (A) 0.5
    • ITRIP
      (A)
      1
    • Max Volts
      (V)
      24
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      0.15
    • R1max
      (Ω)
      0.75
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.1
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1206L075
    • IHold (A) 0.75
    • ITRIP
      (A)
      1.5
    • Max Volts
      (V)
      6
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      0.09
    • R1max
      (Ω)
      0.29
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.2
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Catalog # 1206L075/13.2
    • IHold (A) 0.75
    • ITRIP
      (A)
      1.5
    • Max Volts
      (V)
      13.2
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      0.09
    • R1max
      (Ω)
      0.35
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.2
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1206L075/16
    • IHold (A) 0.75
    • ITRIP
      (A)
      1.5
    • Max Volts
      (V)
      16
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      0.09
    • R1max
      (Ω)
      0.29
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.2
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1206L075TH
    • IHold (A) 0.75
    • ITRIP
      (A)
      1.5
    • Max Volts
      (V)
      8
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      0.09
    • R1max
      (Ω)
      0.29
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.2
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1206L110TH
    • IHold (A) 1.1
    • ITRIP
      (A)
      2.2
    • Max Volts
      (V)
      8
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.04
    • R1max
      (Ω)
      0.18
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.3
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1206L150TH
    • IHold (A) 1.5
    • ITRIP
      (A)
      3
    • Max Volts
      (V)
      6
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.04
    • R1max
      (Ω)
      0.12
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.3
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1206L175
    • IHold (A) 1.75
    • ITRIP
      (A)
      3.5
    • Max Volts
      (V)
      6
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.02
    • R1max
      (Ω)
      0.09
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.5
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1206L200
    • IHold (A) 2
    • ITRIP
      (A)
      3.5
    • Max Volts
      (V)
      6
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.018
    • R1max
      (Ω)
      0.08
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      1.5
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample