Surface Mount PPTCs

1812L

  • Electrical Characteristics
    • Catalog # 1812L010
    • IHold (A) 0.1
    • ITRIP
      (A)
      0.3
    • Max Volts
      (V)
      30
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      1.6
    • R1max
      (Ω)
      15
    • Max
      Time
      To
      Trip
      (A)
      0.5
    • Max
      Time
      to
      Trip Time
      (Sec)
      1.5
    • RTYP
      (Ω)
      7
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L010/60
    • IHold (A) 0.1
    • ITRIP
      (A)
      0.3
    • Max Volts
      (V)
      60
    • IMAX
      (A)
      10
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      1.6
    • R1max
      (Ω)
      15
    • Max
      Time
      To
      Trip
      (A)
      0.5
    • Max
      Time
      to
      Trip Time
      (Sec)
      1.5
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L014
    • IHold (A) 0.14
    • ITRIP
      (A)
      0.34
    • Max Volts
      (V)
      60
    • IMAX
      (A)
      10
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      1.5
    • R1max
      (Ω)
      6
    • Max
      Time
      To
      Trip
      (A)
      1.5
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.15
    • RTYP
      (Ω)
      4
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L020
    • IHold (A) 0.2
    • ITRIP
      (A)
      0.4
    • Max Volts
      (V)
      30
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.8
    • R1max
      (Ω)
      5
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.02
    • RTYP
      (Ω)
      2.9
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L020/60
    • IHold (A) 0.2
    • ITRIP
      (A)
      0.4
    • Max Volts
      (V)
      60
    • IMAX
      (A)
      40
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      1.4
    • R1max
      (Ω)
      4.4
    • Max
      Time
      To
      Trip
      (A)
      1
    • Max
      Time
      to
      Trip Time
      (Sec)
      2
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L035/30
    • IHold (A) 0.35
    • ITRIP
      (A)
      0.75
    • Max Volts
      (V)
      30
    • IMAX
      (A)
      40
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.4
    • R1max
      (Ω)
      1.7
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.15
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L050
    • IHold (A) 0.5
    • ITRIP
      (A)
      1
    • Max Volts
      (V)
      15
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.15
    • R1max
      (Ω)
      1
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.15
    • RTYP
      (Ω)
      0.6
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L050/30
    • IHold (A) 0.5
    • ITRIP
      (A)
      1
    • Max Volts
      (V)
      30
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.15
    • R1max
      (Ω)
      1
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.15
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L050/60
    • IHold (A) 0.5
    • ITRIP
      (A)
      1
    • Max Volts
      (V)
      60
    • IMAX
      (A)
      10
    • PDMAX
      (W)
      1.5
    • RMIN
      (Ω)
      0.15
    • R1max
      (Ω)
      1
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.15
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L075
    • IHold (A) 0.75
    • ITRIP
      (A)
      1.5
    • Max Volts
      (V)
      13.2
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.1
    • R1max
      (Ω)
      0.45
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.2
    • RTYP
      (Ω)
      0.26
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L075/24
    • IHold (A) 0.75
    • ITRIP
      (A)
      1.5
    • Max Volts
      (V)
      24
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.11
    • R1max
      (Ω)
      0.29
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.2
    • RTYP
      (Ω)
      0.2
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L075/33
    • IHold (A) 0.75
    • ITRIP
      (A)
      1.5
    • Max Volts
      (V)
      33
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.11
    • R1max
      (Ω)
      0.4
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.2
    • RTYP
      (Ω)
      0.26
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L110
    • IHold (A) 1.1
    • ITRIP
      (A)
      2.2
    • Max Volts
      (V)
      8
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.04
    • R1max
      (Ω)
      0.21
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.3
    • RTYP
      (Ω)
      0.12
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L110/16
    • IHold (A) 1.1
    • ITRIP
      (A)
      1.95
    • Max Volts
      (V)
      16
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.06
    • R1max
      (Ω)
      0.18
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.5
    • RTYP
      (Ω)
      0.12
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L110/24
    • IHold (A) 1.1
    • ITRIP
      (A)
      1.95
    • Max Volts
      (V)
      24
    • IMAX
      (A)
      20
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.06
    • R1max
      (Ω)
      0.2
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.5
    • RTYP
      (Ω)
      0.12
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L110/33
    • IHold (A) 1.1
    • ITRIP
      (A)
      1.95
    • Max Volts
      (V)
      33
    • IMAX
      (A)
      20
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.06
    • R1max
      (Ω)
      0.2
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.5
    • RTYP
      (Ω)
      0.12
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L125
    • IHold (A) 1.25
    • ITRIP
      (A)
      2.5
    • Max Volts
      (V)
      16
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.05
    • R1max
      (Ω)
      0.14
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.4
    • RTYP
      (Ω)
      0.09
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Catalog # 1812L125/16
    • IHold (A) 1.25
    • ITRIP
      (A)
      2.5
    • Max Volts
      (V)
      16
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.05
    • R1max
      (Ω)
      0.14
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.4
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L125/6
    • IHold (A) 1.25
    • ITRIP
      (A)
      2.5
    • Max Volts
      (V)
      6
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.05
    • R1max
      (Ω)
      0.14
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.4
    • RTYP
      (Ω)
      0.09
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L150
    • IHold (A) 1.25
    • ITRIP
      (A)
      3
    • Max Volts
      (V)
      8
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.04
    • R1max
      (Ω)
      0.11
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.3
    • RTYP
      (Ω)
      0.07
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L150/12
    • IHold (A) 1.5
    • ITRIP
      (A)
      3
    • Max Volts
      (V)
      12
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.04
    • R1max
      (Ω)
      0.11
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.5
    • RTYP
      (Ω)
      0.07
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L150/16
    • IHold (A) 1.5
    • ITRIP
      (A)
      3
    • Max Volts
      (V)
      16
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.04
    • R1max
      (Ω)
      0.11
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.5
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L150/24
    • IHold (A) 1.5
    • ITRIP
      (A)
      3
    • Max Volts
      (V)
      24
    • IMAX
      (A)
      20
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.04
    • R1max
      (Ω)
      0.12
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      1.5
    • RTYP
      (Ω)
      0.07
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L160
    • IHold (A) 1.6
    • ITRIP
      (A)
      2.8
    • Max Volts
      (V)
      8
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.03
    • R1max
      (Ω)
      0.1
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      1
    • RTYP
      (Ω)
      0.066
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L160/12
    • IHold (A) 1.6
    • ITRIP
      (A)
      2.8
    • Max Volts
      (V)
      12
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.03
    • R1max
      (Ω)
      0.1
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      1
    • RTYP
      (Ω)
      0.066
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L160/8
    • IHold (A) 1.6
    • ITRIP
      (A)
      2.8
    • Max Volts
      (V)
      8
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • R1max
      (Ω)
      0.1
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      1
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock
    • Catalog # 1812L200
    • IHold (A) 2
    • ITRIP
      (A)
      3.5
    • Max Volts
      (V)
      8
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.02
    • R1max
      (Ω)
      0.06
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      2
    • RTYP
      (Ω)
      0.04
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Catalog # 1812L200/12
    • IHold (A) 2
    • ITRIP
      (A)
      3.5
    • Max Volts
      (V)
      12
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      2
    • RMIN
      (Ω)
      0.02
    • R1max
      (Ω)
      0.07
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      2
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L200/16
    • IHold (A) 2
    • ITRIP
      (A)
      3.5
    • Max Volts
      (V)
      16
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      1
    • RMIN
      (Ω)
      0.02
    • R1max
      (Ω)
      0.07
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      2
    • RTYP
      (Ω)
      0.04
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock
    • Catalog # 1812L200TH
    • IHold (A) 2
    • ITRIP
      (A)
      4
    • Max Volts
      (V)
      8
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.02
    • R1max
      (Ω)
      0.07
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      2
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L260
    • IHold (A) 2.6
    • ITRIP
      (A)
      5
    • Max Volts
      (V)
      6
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.015
    • R1max
      (Ω)
      0.047
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      2.5
    • RTYP
      (Ω)
      0.03
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Catalog # 1812L260/12
    • IHold (A) 2.6
    • ITRIP
      (A)
      5
    • Max Volts
      (V)
      12
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.015
    • R1max
      (Ω)
      0.055
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      5
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L260/16
    • IHold (A) 2.6
    • ITRIP
      (A)
      5
    • Max Volts
      (V)
      16
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      1.2
    • RMIN
      (Ω)
      0.015
    • R1max
      (Ω)
      0.05
    • Max
      Time
      To
      Trip
      (A)
      16
    • Max
      Time
      to
      Trip Time
      (Sec)
      5
    • RTYP
      (Ω)
      0.03
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L260TH
    • IHold (A) 2.6
    • ITRIP
      (A)
      5
    • Max Volts
      (V)
      8
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.015
    • R1max
      (Ω)
      0.047
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      2.5
    • RTYP
      (Ω)
      0.03
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1812L300
    • IHold (A) 3
    • ITRIP
      (A)
      5
    • Max Volts
      (V)
      6
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.012
    • R1max
      (Ω)
      0.04
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      4
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample