background-waves

TRF600-150

Product Status| Activei

TRF600-150

TRF600-150 | Series: TRF600
info

Our PolySwitch® families of telecommunications and networking devices help meet the growing demand for resettable overcurrent protection. These product families help provide protection against damage caused by power cross and power induction surges as defined in ITU, Telcordia GR1089 and IEC 62368-1. Our offering includes chip, surface-mount and radial-leaded configurations.

PropertyValue
IH (A)
0.15
Trip Current (A)
0.3
Max Voltage Rating (V)
250
RMIN (Ω)
6
Resistance (Max) (Ω)
10
R1max (Ω)
17
Interrupt Current Max
3
Interrupt Voltage (Max) V
600
Max Operating Temperature (°C)
85
Power Dissipation (Typical) (W)
1.4
  • Resettable overcurrent protection
  • Fast time-to-trip
  • Resistance sorted and matched devices available
  • Low parasitic capacitance/flat impedance with frequency
  • Recognized to UL 1434, approved to CSA TIL No. CA-3A and EN 60730-1

TRF600-150 Applications

Highlights Section

  • Networking equipment and telecom systems
  • Modems
  • Phone sets
  • Fax machines
  • Phone wall outlets
  • Alarm systems
  • PBX systems
  • MDF modules
  • T1/E1 equipment
  • Analog and digital line cards

TRF600-150 Resources

Showing 1 to 1 of 1 Total Results
Download
|
Share
Part NumberPart DescriptionRoHSPb-FreeRoHS (2015/863/EU) CertificateREACH (SVHC's) DeclarationREACH (SVHC's)Halogen FreeIPC-Material Declaration
A87878-000TRF600-150RoHS7/26/2017Pb-Free7/26/2017Pdf IconCoC_RoHS10_A87878-000_(TRF600-150)Pdf IconREACH_SVHC Declaration_A87878-000 (TRF600-150)Does Not ContainYes7/26/2017