The PGR-4700 series relay operates on solidly-grounded and resistance-grounded ac systems. This sensitive ground-fault relay provides exceptional low-level protection without the issues associated with high-sensitivity nuisance tripping. It detects very low-level leakage current on large circuits to avoid or significantly reduce equipment damage and injury to personnel. The leakages can be identified as they develop, and ground-faults can be detected before they become critical. The PGR-4700 is compatible with variable frequency drive applications. These ground-fault relays can be used for the protection of critical circuits in panel boards and switchboards, OEM power distribution panels, and custom controls. They are typically used in critical load applications with costly downtime and hazards such as high humidity, water, dust, chemicals, and vibration.
- Adjustable trip level settings from 10 mA to 3.0 A
- Advanced harmonic filtering
- Compatible with VFD applications
- Adjustable time delay
- Metering output with PLC interface
- CT loop monitoring
- POWR-GARD® technology
- Adjustable trip setting provides a wide range of protection
- Eliminates nuisance tripping
- Variable frequency drive compatibility/protection
- Allows quick protection and system coordination
- Continuous system monitoring
- Alarms when CT is not connected
- Superior protection against electrical system damage
PGR-4700 Parts
Filters
Part Number | Actions | Supply Voltage AC | Supply Voltage DC | Relay Contacts Config | Analog Output Current (mA) | IEEE Device Numbers | Relay Contacts Operation | Weight (kg) | Auto Manual Reset | Conformally Coated | CT Loop Monitoring | GF Trip Level A | GF Trip Time (s) | Harmonic Filtering | Reset Type | System Type | Test Button |
---|
Part Number | Actions | Supply Voltage AC | Supply Voltage DC | Relay Contacts Config | Analog Output Current (mA) | IEEE Device Numbers | Relay Contacts Operation | Weight (kg) | Auto Manual Reset | Conformally Coated | CT Loop Monitoring | GF Trip Level A | GF Trip Time (s) | Harmonic Filtering | Reset Type | System Type | Test Button | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
120 | 2 Form C (N.O./N.C.) | 0 - 1 | 50G - 50N - 51G - 51N | Fail-safe / Non Fail-safe | 0 Kg (kilogram) | Latching; Autoreset | Optional | Standard | 0.01 - 3.0 | 0.0 - 1.5 | Standard | Front-panel switch | Solidly Grounded AC | Front-panel switch | ||||
24 | 24 | 2 Form C (N.O./N.C.) | 0 - 1 | 50G - 50N - 51G - 51N | Fail-safe / Non Fail-safe | 0 Kg (kilogram) | Latching; Autoreset | Optional | Standard | 0.01 - 3.0 | 0.0 - 1.5 | Standard | Front-panel switch | Solidly Grounded AC | Front-panel switch | |||
240 | 2 Form C (N.O./N.C.) | 0 - 1 | 50G - 50N - 51G - 51N | Fail-safe / Non Fail-safe | 0 Kg (kilogram) | Latching; Autoreset | Optional | Standard | 0.01 - 3.0 | 0.0 - 1.5 | Standard | Front-panel switch | Solidly Grounded AC | Front-panel switch |
PGR-4700 Applications
- Solidly grounded and resistance-grounded ac systems