The ISS-105 is a “smart” five-channel intrinsically safe relay and pump controller. The ISS-105 can be configured for a wide variety of applications including alternating or non-alternating duplex, duplex separate pump stop (SPS), triplex and quadplex applications. It can be set up for pump-up or pump-down applications or can be used as a five-channel relay.
The ISS-105 has a long list of features that are needed for multiple pump applications. The ISS-105 can indicate low, high and out-of-sequence alarms. If an out-of-sequence alarm occurs, the skipped pump(s) will be started as intended. The Model ISS-105 can be set up to do non-alternating control, alternating control and alternating control with one non-alternating pump. The non-alternating pump is intended for use with an emergency or jockey pump. The ISS-105 can start an emergency pump once every 50 cycles to keep it working freely. Using the built-in DIP switches, individual pumps can be disabled when taken out of service for repair or maintenance.
- 5 intrinsically-safe input channels meeting UL913 Sixth Edition
- 4 normally open output relays and 1 SPDT output relay
- Field selectable pump control options
- Monitors float sequencing and sends signal to alarm if out-of-sequence condition occurs
- High and/or low alarm options depending on the number of pumps and settings
- Output contacts for audible alarm
- Meets IEC EMC standards for Electrical Fast Transients (EFT), Electrostatic Discharge (ESD) and Radio Frequency Immunity (RFI)
- DIN rail or surface mountable allows flexibility in panel installation
- User-selectable alternator/non-alternator option
- User-selectable alternator/non-alternator option
ISS 105 Parts
Filters
Showing 1 to 7 of 7 Total Results
Part Number | Actions | Input Voltage (V) | Termination Type | Mount Method | Dimensions | Weight (kg) | Debounce Time Delay (s) | Humidity | Input AC Line Frequency (Hz) | Input Logic | Input Tolerance (%) | Intrinsically Safe Circuit Location | Maximum Input Power (W) | Output Load Rating (VA) | Protection Class | Sense Voltage |
---|
Part Number | Actions | Input Voltage (V) | Termination Type | Mount Method | Dimensions | Weight (kg) | Debounce Time Delay (s) | Humidity | Input AC Line Frequency (Hz) | Input Logic | Input Tolerance (%) | Intrinsically Safe Circuit Location | Maximum Input Power (W) | Output Load Rating (VA) | Protection Class | Sense Voltage | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
120 Vac | Torque: 3.5 to 4.5 in-lbs (max. 6 in.-lbs); Wire: 12 - 20 AWG | 2.35 H x 3.7 W x 5.03 D in. (59.7 x 94.1 x 127.6 mm) | 0 Kg (kilogram) | 10 - 95% non-condensing per IEC 68-2-3 | 50 / 60 (50 will increase all delay timers by 20%) | ±10% | Division 1 and 2; Class I Groups A B C D; Class II Groups E F G; Class III | 5 | Pilot Duty: 480 VA @ 240 Vac B300; General Purpose: 7 A @ 240 Vac | IP20 (finger safe) | 5 Vdc continuous (probe) | ||||||
120 Vac | Torque: 3.5 to 4.5 in-lbs (max. 6 in.-lbs); Wire: 12 - 20 AWG | 2.35 H x 3.7 W x 5.03 D in. (59.7 x 94.1 x 127.6 mm) | 0 Kg (kilogram) | 2 | 10 - 95% non-condensing per IEC 68-2-3 | 50 / 60 (50 will increase all delay timers by 20%) | Input/Output Channels: 5 channels | ±10% | Division 1 and 2; Class I Groups A B C D; Class II Groups E F G; Class III | 5 | Pilot Duty: 480 VA @ 240 Vac B300; General Purpose: 7 A @ 240 Vac | IP20 (finger safe) | 5 Vdc continuous (probe) | ||||
120 Vac | Torque: 3.5 to 4.5 in-lbs (max. 6 in.-lbs); Wire: 12 - 20 AWG | 2.35 H x 3.7 W x 5.03 D in. (59.7 x 94.1 x 127.6 mm) | 0 Kg (kilogram) | 2 | 10 - 95% non-condensing per IEC 68-2-3 | 50 / 60 (50 will increase all delay timers by 20%) | Input/Output Channels: 3 channels | ±10% | Division 1 and 2; Class I Groups A B C D; Class II Groups E F G; Class III | 5 | Pilot Duty: 480 VA @ 240 Vac B300; General Purpose: 7 A @ 240 Vac | IP20 (finger safe) | 5 Vdc continuous (probe) | ||||
120 Vac | Torque: 3.5 to 4.5 in-lbs (max. 6 in.-lbs); Wire: 12 - 20 AWG | 2.35 H x 3.7 W x 5.03 D in. (59.7 x 94.1 x 127.6 mm) | 0 Kg (kilogram) | 2 | 10 - 95% non-condensing per IEC 68-2-3 | 50 / 60 (50 will increase all delay timers by 20%) | Input/Output Channels: 4 channels | ±10% | Division 1 and 2; Class I Groups A B C D; Class II Groups E F G; Class III | 5 | Pilot Duty: 480 VA @ 240 Vac B300; General Purpose: 7 A @ 240 Vac | IP20 (finger safe) | 5 Vdc continuous (probe) | ||||
120 Vac | Torque: 3.5 to 4.5 in-lbs (max. 6 in.-lbs); Wire: 12 - 20 AWG | 2.35 H x 3.7 W x 5.03 D in. (59.7 x 94.1 x 127.6 mm) | 0 Kg (kilogram) | 2 | 10 - 95% non-condensing per IEC 68-2-3 | 50 / 60 (50 will increase all delay timers by 20%) | Input/Output Channels: 5 channels faster response time (≤75 s) | ±10% | Division 1 and 2; Class I Groups A B C D; Class II Groups E F G; Class III | 5 | Pilot Duty: 480 VA @ 240 Vac B300; General Purpose: 7 A @ 240 Vac | IP20 (finger safe) | 5 Vdc continuous (probe) | ||||
0 Kg (kilogram) | |||||||||||||||||
0 Kg (kilogram) |