The 601-CS-D-P1 series is a fully programmable, electronic, three-phase, power monitor designed to monitor three-phase systems. This unit has a single relay that can be configured as a general purpose network output or to trip on ground faults. The 601-CS-D-P1 monitors ground-fault current, phase currents, phase voltages, power factor, and frequency. The RS485MS-2W communications module allows the 601-CS-D-P1 to communicate using the Modbus RTU protocol. The Modbus connection can be used to monitor power parameters, set up the device or control the fault relay. A DeviceNet™ communications I/O module (CIO-601CS-DN-P1) is also available. This CIO module only works with the 601-CS-D-P1 unit. It is used for sending the information from the 601-CS-D-P1 over a DeviceNet™ network. It also provides I/O capabilities and the ability to set the parameters of the 601-CS-D-P1.
The 601-CS-D-P1 includes a built-in display that offers a visual indication for programming and viewing real-time parameters for nominal voltage, voltage unbalance, current, current unbalance, ground-fault warning, ground-fault trip, and ground-fault motor acceleration.
Note: This product must be used with an external zero-sequence CT (not included) for proper operation.
- Built-in display
- 15 programmable parameters to control operations
- Two programmable trip delay timers
- Network communications capability
- Visual indication for programming and viewing real-time parameters such as nominal voltage, voltage unbalance, current unbalance, ground-fault warning
- Allows the user to customize the protection required for a specific system
- Program separate trip delay time for motor acceleration and ground fault
- Compatible with Modbus RTU and DeviceNet™ protocols with the use of separate communications module
601 CS D P1 Parts
Filters
Part Number | Actions | Input Voltage (V) | Output Form | Termination Type | Mount Method | Full Load Amp Range (A) | Dimensions | Weight (kg) | Communications Protocol | Current Accuracy (%) | Ground Fault Accuracy (%) | Humidity | Input AC Line Frequency (Hz) | Maximum Input Power (W) | Output Load Rating (VA) | Pollution Degree | Protection Class | Repeat Accuracy (%) | Storage temperature (°C) | Surge Protection | Voltage Accuracy (%) |
---|
Part Number | Actions | Input Voltage (V) | Output Form | Termination Type | Mount Method | Full Load Amp Range (A) | Dimensions | Weight (kg) | Communications Protocol | Current Accuracy (%) | Ground Fault Accuracy (%) | Humidity | Input AC Line Frequency (Hz) | Maximum Input Power (W) | Output Load Rating (VA) | Pollution Degree | Protection Class | Repeat Accuracy (%) | Storage temperature (°C) | Surge Protection | Voltage Accuracy (%) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
200 - 480 Vac | SPDT | Torque: 7 in-lbs | 0.5 - 175 (direct); 176 - 800 (external CTs required) | 3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm) | 0 Kg (kilogram) | Modbus RTU | ±3% (<100 A direct) | ±3% | 10 - 95% non-condensing per IEC 68-2-3 | 50 / 60 | 10 | Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A @ 240 Vac | 3 | IP20 (finger safe) | Voltage: ±0.5% of nominal voltage; Current: ±1% (<175 A direct) | IEC: 61000-4-5 Level 3 2 kV line-to-line; Level 4 4 kV line-to-ground | ±1% |
601 CS D P1 Applications
- For monitoring a zero-sequence current transformer for ground-fault protection