  • Electrical Characteristics
    • Catalog # ORB24A21D
    • Input Voltage (V) 24 V ac
    • Input Tolerance (%) -15% - 20%
    • Input AC Line Frequency (Hz) 50/60
    • Output Type Electromechanical relay
    • Output Form Isolated SPDT or DPDT
    • Output Load Rating (VA) 10 A resistive @ 120/240 V ac and 28 V dc; 1/3 hp @ 120/240 V ac
    • Time Delay Type Analog
    • Time Delay Range 0.05 - 3 s onboard adjustable
    • Time Delay Tolerance (%) Guaranteed range
    • Reset Time (ms) ≤50
    • Initiate Time (ms) ≤70
    • Repeat Accuracy (%) ±2% or 20 ms whichever is greater
    • Setpoint vs Ambient Temperature and Operating Voltage (%) ≤±10%
    • Life Electrical: 1 x 10⁵; Mechanical: 1 x 10⁷
    • Power Consumption 2.25 W
    • Termination Type 0.25 in. (6.35 mm) male quick connect terminals
    • Mounting Method Surface mount with 4 #6 (M3.5 x 0.6) screws
    • Operating Temperature -20° to 65°C (-4° to 149°F)
    • Storage Temperature (F/C) -30° to 85°C (-22° to 185°F)