MICRO TR3 Fuses

303

  • Electrical Characteristics
    • Catalog # 30300500001
    • Amps (A) 0.05
    • VAC (V) 125
    • Resistance
      (Ω)
      2.92
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.00007
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      40
    • Nom
      Voltage
      Drop
      (mV)
      800
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30300500131
    • Amps (A) 0.05
    • VAC (V) 125
    • Resistance
      (Ω)
      2.92
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.00007
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      40
    • Nom
      Voltage
      Drop
      (mV)
      800
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30300500421
    • Amps (A) 0.05
    • VAC (V) 125
    • Resistance
      (Ω)
      2.92
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.00007
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      40
    • Nom
      Voltage
      Drop
      (mV)
      800
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30300630001
    • Amps (A) 0.063
    • VAC (V) 125
    • Resistance
      (Ω)
      1.199
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.00013
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      50
    • Nom
      Voltage
      Drop
      (mV)
      780
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30300630131
    • Amps (A) 0.063
    • VAC (V) 125
    • Resistance
      (Ω)
      1.199
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.00013
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      50
    • Nom
      Voltage
      Drop
      (mV)
      780
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30300630421
    • Amps (A) 0.063
    • VAC (V) 125
    • Resistance
      (Ω)
      1.199
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.00013
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      50
    • Nom
      Voltage
      Drop
      (mV)
      780
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30300800001
    • Amps (A) 0.08
    • VAC (V) 125
    • Resistance
      (Ω)
      2.23
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.0002
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      60
    • Nom
      Voltage
      Drop
      (mV)
      730
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30300800131
    • Amps (A) 0.08
    • VAC (V) 125
    • Resistance
      (Ω)
      2.23
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.0002
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      60
    • Nom
      Voltage
      Drop
      (mV)
      730
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30300800421
    • Amps (A) 0.08
    • VAC (V) 125
    • Resistance
      (Ω)
      2.23
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.0002
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      60
    • Nom
      Voltage
      Drop
      (mV)
      730
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30301000001
    • Amps (A) 0.1
    • VAC (V) 125
    • Resistance
      (Ω)
      4.38
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.0004
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      70
    • Nom
      Voltage
      Drop
      (mV)
      700
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30301000131
    • Amps (A) 0.1
    • VAC (V) 125
    • Resistance
      (Ω)
      4.38
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.0004
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      70
    • Nom
      Voltage
      Drop
      (mV)
      700
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30301000421
    • Amps (A) 0.1
    • VAC (V) 125
    • Resistance
      (Ω)
      4.38
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.0004
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      70
    • Nom
      Voltage
      Drop
      (mV)
      700
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30301250001
    • Amps (A) 0.125
    • VAC (V) 125
    • Resistance
      (Ω)
      3.461
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.0022
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      85
    • Nom
      Voltage
      Drop
      (mV)
      650
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30301250131
    • Amps (A) 0.125
    • VAC (V) 125
    • Resistance
      (Ω)
      3.461
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.0022
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      85
    • Nom
      Voltage
      Drop
      (mV)
      650
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30301250421
    • Amps (A) 0.125
    • VAC (V) 125
    • Resistance
      (Ω)
      3.461
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.0022
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      85
    • Nom
      Voltage
      Drop
      (mV)
      650
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30301600001
    • Amps (A) 0.16
    • VAC (V) 125
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.0029
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      100
    • Nom
      Voltage
      Drop
      (mV)
      600
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30301600131
    • Amps (A) 0.16
    • VAC (V) 125
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.0029
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      100
    • Nom
      Voltage
      Drop
      (mV)
      600
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30301600421
    • Amps (A) 0.16
    • VAC (V) 125
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.0029
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      100
    • Nom
      Voltage
      Drop
      (mV)
      600
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30302000001
    • Amps (A) 0.2
    • VAC (V) 125
    • Resistance
      (Ω)
      1.35
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.0042
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      110
    • Nom
      Voltage
      Drop
      (mV)
      550
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30302000131
    • Amps (A) 0.2
    • VAC (V) 125
    • Resistance
      (Ω)
      1.35
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.0042
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      110
    • Nom
      Voltage
      Drop
      (mV)
      550
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30302000421
    • Amps (A) 0.2
    • VAC (V) 125
    • Resistance
      (Ω)
      1.35
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.0042
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      110
    • Nom
      Voltage
      Drop
      (mV)
      550
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30302500001
    • Amps (A) 0.25
    • VAC (V) 125
    • Resistance
      (Ω)
      1.15
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.0082
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      125
    • Nom
      Voltage
      Drop
      (mV)
      500
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30302500131
    • Amps (A) 0.25
    • VAC (V) 125
    • Resistance
      (Ω)
      1.15
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.0082
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      125
    • Nom
      Voltage
      Drop
      (mV)
      500
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30302500421
    • Amps (A) 0.25
    • VAC (V) 125
    • Resistance
      (Ω)
      1.15
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.0082
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      125
    • Nom
      Voltage
      Drop
      (mV)
      500
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30303150001
    • Amps (A) 0.315
    • VAC (V) 125
    • Resistance
      (Ω)
      0.965
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.015
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      145
    • Nom
      Voltage
      Drop
      (mV)
      450
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30303150131
    • Amps (A) 0.315
    • VAC (V) 125
    • Resistance
      (Ω)
      0.965
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.015
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      145
    • Nom
      Voltage
      Drop
      (mV)
      450
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30303150421
    • Amps (A) 0.315
    • VAC (V) 125
    • Resistance
      (Ω)
      0.965
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.015
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      145
    • Nom
      Voltage
      Drop
      (mV)
      450
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30304000001
    • Amps (A) 0.4
    • VAC (V) 125
    • Resistance
      (Ω)
      0.805
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.025
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      160
    • Nom
      Voltage
      Drop
      (mV)
      400
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30304000131
    • Amps (A) 0.4
    • VAC (V) 125
    • Resistance
      (Ω)
      0.805
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.025
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      160
    • Nom
      Voltage
      Drop
      (mV)
      400
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30304000421
    • Amps (A) 0.4
    • VAC (V) 125
    • Resistance
      (Ω)
      0.805
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.025
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      160
    • Nom
      Voltage
      Drop
      (mV)
      400
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30305000001
    • Amps (A) 0.5
    • VAC (V) 125
    • Resistance
      (Ω)
      0.532
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.042
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      190
    • Nom
      Voltage
      Drop
      (mV)
      380
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30305000131
    • Amps (A) 0.5
    • VAC (V) 125
    • Resistance
      (Ω)
      0.532
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.042
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      190
    • Nom
      Voltage
      Drop
      (mV)
      380
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30305000421
    • Amps (A) 0.5
    • VAC (V) 125
    • Resistance
      (Ω)
      0.532
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.042
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      190
    • Nom
      Voltage
      Drop
      (mV)
      380
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30306300001
    • Amps (A) 0.63
    • VAC (V) 125
    • Resistance
      (Ω)
      0.1448
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.015
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      100
    • Nom
      Voltage
      Drop
      (mV)
      160
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30306300131
    • Amps (A) 0.63
    • VAC (V) 125
    • Resistance
      (Ω)
      0.1448
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.015
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      100
    • Nom
      Voltage
      Drop
      (mV)
      160
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30306300421
    • Amps (A) 0.63
    • VAC (V) 125
    • Resistance
      (Ω)
      0.1448
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.015
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      100
    • Nom
      Voltage
      Drop
      (mV)
      160
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30308000001
    • Amps (A) 0.8
    • VDC (V) 125
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.025
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      125
    • Nom
      Voltage
      Drop
      (mV)
      155
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30308000131
    • Amps (A) 0.8
    • VDC (V) 125
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.025
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      125
    • Nom
      Voltage
      Drop
      (mV)
      155
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30308000421
    • Amps (A) 0.8
    • VDC (V) 125
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.025
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      125
    • Nom
      Voltage
      Drop
      (mV)
      155
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30311000001
    • Amps (A) 1
    • VDC (V) 125
    • Resistance
      (Ω)
      0.08345
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.039
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      155
    • Nom
      Voltage
      Drop
      (mV)
      150
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30311000131
    • Amps (A) 1
    • VDC (V) 125
    • Resistance
      (Ω)
      0.08345
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.039
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      155
    • Nom
      Voltage
      Drop
      (mV)
      150
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30311000421
    • Amps (A) 1
    • VDC (V) 125
    • Resistance
      (Ω)
      0.08345
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.039
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      155
    • Nom
      Voltage
      Drop
      (mV)
      150
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30311250001
    • Amps (A) 1.25
    • VDC (V) 125
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.059
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      185
    • Nom
      Voltage
      Drop
      (mV)
      145
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30311250131
    • Amps (A) 1.25
    • VDC (V) 125
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.059
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      185
    • Nom
      Voltage
      Drop
      (mV)
      145
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30311250421
    • Amps (A) 1.25
    • VDC (V) 125
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.059
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      185
    • Nom
      Voltage
      Drop
      (mV)
      145
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30311600001
    • Amps (A) 1.6
    • VDC (V) 125
    • Resistance
      (Ω)
      0.052
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.11
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      225
    • Nom
      Voltage
      Drop
      (mV)
      140
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30311600131
    • Amps (A) 1.6
    • VDC (V) 125
    • Resistance
      (Ω)
      0.052
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.11
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      225
    • Nom
      Voltage
      Drop
      (mV)
      140
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30311600421
    • Amps (A) 1.6
    • VDC (V) 125
    • Resistance
      (Ω)
      0.052
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.11
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      225
    • Nom
      Voltage
      Drop
      (mV)
      140
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30312000001
    • Amps (A) 2
    • VDC (V) 125
    • Resistance
      (Ω)
      0.04
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.17
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      260
    • Nom
      Voltage
      Drop
      (mV)
      130
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30312000131
    • Amps (A) 2
    • VDC (V) 125
    • Resistance
      (Ω)
      0.04
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.17
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      260
    • Nom
      Voltage
      Drop
      (mV)
      130
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30312000421
    • Amps (A) 2
    • VDC (V) 125
    • Resistance
      (Ω)
      0.04
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.17
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      260
    • Nom
      Voltage
      Drop
      (mV)
      130
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30312500001
    • Amps (A) 2.5
    • VDC (V) 125
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.23
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      315
    • Nom
      Voltage
      Drop
      (mV)
      125
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30312500131
    • Amps (A) 2.5
    • VDC (V) 125
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.23
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      315
    • Nom
      Voltage
      Drop
      (mV)
      125
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30312500421
    • Amps (A) 2.5
    • VDC (V) 125
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.23
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      315
    • Nom
      Voltage
      Drop
      (mV)
      125
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30313150001
    • Amps (A) 3.15
    • VDC (V) 125
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.45
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      380
    • Nom
      Voltage
      Drop
      (mV)
      120
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30313150131
    • Amps (A) 3.15
    • VDC (V) 125
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.45
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      380
    • Nom
      Voltage
      Drop
      (mV)
      120
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30313150421
    • Amps (A) 3.15
    • VDC (V) 125
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 0.45
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      380
    • Nom
      Voltage
      Drop
      (mV)
      120
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30314000001
    • Amps (A) 4
    • VDC (V) 125
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 1
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      440
    • Nom
      Voltage
      Drop
      (mV)
      110
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30314000131
    • Amps (A) 4
    • VDC (V) 125
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 1
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      440
    • Nom
      Voltage
      Drop
      (mV)
      110
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30314000421
    • Amps (A) 4
    • VDC (V) 125
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 1
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      440
    • Nom
      Voltage
      Drop
      (mV)
      110
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30315000001
    • Amps (A) 5
    • VDC (V) 125
    • Resistance
      (Ω)
      0.0131
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 1.5
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      525
    • Nom
      Voltage
      Drop
      (mV)
      105
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30315000131
    • Amps (A) 5
    • VDC (V) 125
    • Resistance
      (Ω)
      0.0131
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 1.5
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      525
    • Nom
      Voltage
      Drop
      (mV)
      105
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 30315000421
    • Amps (A) 5
    • VDC (V) 125
    • Resistance
      (Ω)
      0.0131
    • Interrupting Rating 50A@125VAC
    • Nominal Melting I2T (A2sec) 1.5
    • Min Operating Temp °C -25
    • Max Operating Temp (°C) 70
    • MSL MIL-STD-202 Method 106
    • Nom
      Power
      Dissipation
      (W)
      525
    • Nom
      Voltage
      Drop
      (mV)
      105
    • Opening Fast-Acting (F)
    • Size TR3/MICRO (6x8mm)
    • Datasheet
    • Check Stock Order Sample