Surface Mount PPTCs

1210L

  • Electrical Characteristics
    • Catalog # 1210L005
    • IHold (A) 0.05
    • ITRIP
      (A)
      0.15
    • Max Volts
      (V)
      30
    • IMAX
      (A)
      10
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      3.6
    • R1max
      (Ω)
      50
    • Max
      Time
      To
      Trip
      (A)
      0.25
    • Max
      Time
      to
      Trip Time
      (Sec)
      1.5
    • RTYP
      (Ω)
      25
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1210L005/90
    • IHold (A) 0.05
    • ITRIP
      (A)
      0.15
    • Max Volts
      (V)
      90
    • IMAX
      (A)
      10
    • PDMAX
      (W)
      1.5
    • RMIN
      (Ω)
      3.6
    • R1max
      (Ω)
      50
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.2
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1210L010
    • IHold (A) 0.1
    • ITRIP
      (A)
      0.3
    • Max Volts
      (V)
      30
    • IMAX
      (A)
      10
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      1.6
    • R1max
      (Ω)
      15
    • Max
      Time
      To
      Trip
      (A)
      0.5
    • Max
      Time
      to
      Trip Time
      (Sec)
      1.5
    • RTYP
      (Ω)
      7
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1210L010/90
    • IHold (A) 0.1
    • ITRIP
      (A)
      0.25
    • Max Volts
      (V)
      90
    • IMAX
      (A)
      10
    • PDMAX
      (W)
      1.5
    • RMIN
      (Ω)
      1.5
    • R1max
      (Ω)
      15
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.3
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock
    • Catalog # 1210L020
    • IHold (A) 0.2
    • ITRIP
      (A)
      0.4
    • Max Volts
      (V)
      30
    • IMAX
      (A)
      10
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      0.8
    • R1max
      (Ω)
      5
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.02
    • RTYP
      (Ω)
      2.9
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1210L020/72
    • IHold (A) 0.2
    • ITRIP
      (A)
      0.4
    • Max Volts
      (V)
      72
    • IMAX
      (A)
      10
    • PDMAX
      (W)
      1.5
    • RMIN
      (Ω)
      0.8
    • R1max
      (Ω)
      5
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.5
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1210L035
    • IHold (A) 0.35
    • ITRIP
      (A)
      0.7
    • Max Volts
      (V)
      6
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      0.32
    • R1max
      (Ω)
      1.3
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.2
    • RTYP
      (Ω)
      0.81
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1210L035/30
    • IHold (A) 0.35
    • ITRIP
      (A)
      0.7
    • Max Volts
      (V)
      30
    • IMAX
      (A)
      40
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      0.32
    • R1max
      (Ω)
      1.3
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.2
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1210L035/60
    • IHold (A) 0.35
    • ITRIP
      (A)
      0.7
    • Max Volts
      (V)
      60
    • IMAX
      (A)
      10
    • PDMAX
      (W)
      1.5
    • RMIN
      (Ω)
      0.32
    • R1max
      (Ω)
      1.5
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      1
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1210L050
    • IHold (A) 0.5
    • ITRIP
      (A)
      1
    • Max Volts
      (V)
      13.2
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      0.25
    • R1max
      (Ω)
      0.9
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.1
    • RTYP
      (Ω)
      0.55
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1210L050/30
    • IHold (A) 0.5
    • ITRIP
      (A)
      1
    • Max Volts
      (V)
      30
    • IMAX
      (A)
      40
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      0.22
    • R1max
      (Ω)
      0.9
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.15
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1210L075
    • IHold (A) 0.75
    • ITRIP
      (A)
      1.5
    • Max Volts
      (V)
      6
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      0.13
    • R1max
      (Ω)
      0.4
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.1
    • RTYP
      (Ω)
      0.29
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1210L075/24
    • IHold (A) 0.75
    • ITRIP
      (A)
      1.5
    • Max Volts
      (V)
      24
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      0.13
    • R1max
      (Ω)
      0.4
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.1
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1210L110/12
    • IHold (A) 1.1
    • ITRIP
      (A)
      2.2
    • Max Volts
      (V)
      12
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      0.06
    • R1max
      (Ω)
      0.21
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.1
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1210L110/16
    • IHold (A) 1.1
    • ITRIP
      (A)
      2.2
    • Max Volts
      (V)
      16
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      0.06
    • R1max
      (Ω)
      0.21
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.1
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1210L110TH
    • IHold (A) 1.1
    • ITRIP
      (A)
      2.2
    • Max Volts
      (V)
      6
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.6
    • RMIN
      (Ω)
      0.06
    • R1max
      (Ω)
      0.21
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.3
    • RTYP
      (Ω)
      0.14
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1210L150/16
    • IHold (A) 1.5
    • ITRIP
      (A)
      3
    • Max Volts
      (V)
      16
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.04
    • R1max
      (Ω)
      0.11
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.3
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1210L150TH
    • IHold (A) 1.5
    • ITRIP
      (A)
      3
    • Max Volts
      (V)
      6
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.04
    • R1max
      (Ω)
      0.11
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.5
    • RTYP
      (Ω)
      0.07
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1210L175
    • IHold (A) 1.75
    • ITRIP
      (A)
      3.5
    • Max Volts
      (V)
      6
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.02
    • R1max
      (Ω)
      0.08
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      0.6
    • RTYP
      (Ω)
      0.04
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample
    • Catalog # 1210L200
    • IHold (A) 2
    • ITRIP
      (A)
      4
    • Max Volts
      (V)
      6
    • IMAX
      (A)
      100
    • PDMAX
      (W)
      0.8
    • RMIN
      (Ω)
      0.015
    • R1max
      (Ω)
      0.07
    • Max
      Time
      To
      Trip
      (A)
      8
    • Max
      Time
      to
      Trip Time
      (Sec)
      1
    • RTYP
      (Ω)
      0.04
    • Operating Temperature -40° to 85°C
    • Datasheet
    • Check Stock Order Sample